Basic Info.

Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001, CCC
Usage
Rectifier Transformer, Combined Transformer, Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Silicon Steel Sheet
Brand
Bc Power
Supply Voltage Fluctuation
<+/-5%
Temperature Sampling
Thermistor Ntc Temperature Switch
Isolation Grade
Class H (180 C)
Transport Package
Wooden Case
Specification
2000*1600*2200 mm, 400V/400V-480V-550V-690V-800V
Trademark
BCPOWERCN
Origin
Dongguan City, Guangdong Province, China
Production Capacity
240-360 PCS/Year

Product Description

1. The primary side is 4 loops with 6 contactors are configured each to control the output of 220V/400V/480V/540V/600V/800V separately.
2. Push-button switch is used to control the output of the contactor. Each loop contactor interlock can only have one voltage output.
3. Only the same voltage gear can be used when multiple loops work at the same time.
4. The equipment is equipped with temperature monitoring (winding temperature, core temperature) switching, and the fan is started to cool when the internal temperature is higher than 60 degrees Celsius, and the fan is stopped when the internal temperature is lower than 45 degrees Celsius. Alarm sound occurs when the internal winding temperature exceeds135 degrees Celsius. The transformers automatically shuts down the total input power when the temperature is greater than 150 degrees Celsius.
5. Product total weight 2000KG.

Electric Characteristics
 
1 Connection Group Dyn11
2 Rated capacity of primary winding 3600kW
3 Rated capacity of sencondary winding 3600kW
4 No load voltage:
a1-b1-c1 
a2-b2-c2
a3-b3-c3
a4-b4-c4
a5-b5-c5
400V +/-3%
480V +/-3.5%
550V +/-3%
690V +/-3%
800V +/-3%
5 Load voltage
a1-b1-c1 
a2-b2-c2
a3-b3-c3
a4-b4-c4
a5-b5-c5
400V +/-5%
480V +/-5%
550V +/-5%
690V +/-5%
800V +/-5%
6 Rated current Input 5196A
Output 3012A
7 Mains voltage fluctuation < +/-5%
8 Working frequency 50/60Hz
9 Efficiency >97.5% (350kW resistive load)
10 The load cycle Continous operation
11 Impedence voltage 5%~8%
12 Type of transformer  Dry type
13 The temperature sampling Thermistor (NTC) temperature switch
14 Isolation resistance P,S,E>500MΩ   DC2500V/60s
15 Dielectric strength  <20mA  3KVAC/60s
Coil-Core N1/N2/N3/N4-N5
16 Isolation grade H(180ºC)
17 Allowable temperature rise 95K (rated current, forced air cooling)
18 Noise <70dB (measured with a sound level meter at 1m)
19 Cooling type  AF (Forced air cooling, control panel with independent control switch)
Three Phase Isolating Transformer with CabinetThree Phase Isolating Transformer with CabinetThree Phase Isolating Transformer with CabinetThree Phase Isolating Transformer with CabinetThree Phase Isolating Transformer with Cabinet