• Bcce-Vss (D) Series Regulator
  • Bcce-Vss (D) Series Regulator
  • Bcce-Vss (D) Series Regulator
  • Bcce-Vss (D) Series Regulator
  • Bcce-Vss (D) Series Regulator
  • Bcce-Vss (D) Series Regulator

Bcce-Vss (D) Series Regulator

Current Type: AC
Phase: Three Phase
Frequency Characteristics: Low Frequency
Usage: SVC
Frequency: Low Frequency
Size: Medium
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (17)

Basic Info.

Model NO.
BCCE-VSS(D)-Capacity
Iron Core Shape
Silicon Steel Sheet
Power Source
Switching Regulated Power Supply
Application Range
Widely Used in Industrial, Transportation etc
Brand
Domestic Private Brand
Voltage Regulation Accuracy
Adjustable
Quick Response
12 High-Speed Ad Acquisition,32bit Processor
Protection Function
Overvoltage and Undervoltage Protected in 1 Second
Voltage and Current Display
LCD
Transport Package
Shipping with Wooden Box
Specification
10-2000kVA
Trademark
BCPOWERCN
Origin
Dongguan City, Guangdong Province, China
Production Capacity
3000~5000PCS/Year

Product Description

The intelligent contactless compensation AC voltage regulator is a new generation of fast voltage stabilizer, which has been successfully developed for many years on the basis of the production of compensable power voltage stabilizing equipment.
 

Product description

  1. It uses the latest 32BIT operation processor control technology, fast pure hardware true value 12 Bit voltage sampling technology, voltage / current zero crossing switching technology and unique coding fast contactless compensation voltage regulation technology, which combines intelligent instrument, fast voltage regulator and fault diagnosis together to make the product safe, efficient and precise.
  2. The voltage regulation accuracy is adjustable (voltage tolerance), which is convenient for all kinds of complex application environments.
  3. Output voltage real-time waveform monitoring, we can see at a glance how the power supply quality of the grid is very convenient.
  4. The products are widely used in industrial, transportation, post and telecommunications, national defense, railway, scientific research and other fields of large-scale mechanical and electrical equipment, metal processing equipment, production lines, elevators, medical instruments, embroidery light spinning equipment, air conditioning, radio and television, household appliances and building lighting, such as the need for stable voltage.

 

Quick Response

12 high-speed AD acquisition, weekly wave acquisition 128 points, 32BIT processor for digital processing, electronic module quick compensation.

Arrange Mode

Voltage division: three phase voltages are independently adjusted to ensure that the three phase voltages are within the accuracy range.

Advanced Measurement Technology

12 bit AD acquisition, 32BIT processor for digital filtering and true RMS calculation.

Zero Crossing Detection

Voltage zero crossing and current zero crossing detection are realized, and no contact switch is switched to zero.

Control Precision

Perfect matching of large scale programmable logic device and single chip microcomputer

Humanized Interface

Through operation panel touch key, various indicators can be set (output voltage, voltage precision, protection function).

Output Waveform Without Distortion

Contactless zero switch switching, the same frequency, phase locking, sine wave superposition compensation principle

Resistance to Harmonic Interference

True RMS voltage detection

Wide Range of Load

Resistance, capacitive, emotional load can all be adapted to

Impact Resistance

Adaption to arbitrary load start

Protection Function

In the case of overvoltage and undervoltage, it can be protected or automatically converted to bypass work in 1 second, and has perfect function of phase, overload, short circuit protection and sound and light alarm after failure.

Voltage and Current Display

LCD liquid crystal display with true value of voltage and current respectively

Fault Status Display

Detailed display of various fault states, fault status at a glance

 

Del Rated capacity (KVA) Output current (A) Input voltage (V) output voltage(V) Phase number Pressure resistance(V) insulation resistance() efficiency Waveform distortion working frequency(HZ) stabilized voltage precision response time
BCCE-VSS-10 10 15 304~456 380±1-5%Can be set Three-phase 2000/No breakdown for 1 minutes ≥2 ≥98% ≤0.1% 50~60 ±1% ≤20MS
BCCE- VSS-20 20 30
BCCE-VSS-30 30 46
BCCE-VSS-50 50 76
BCCE-VSS-60 60 91
BCCE-VSS-80 80 122
BCCE-VSS-100 100 152
BCCE-VSS-120 120 182
BCCE-VSS-150 150 228
BCCE-VSS-180 180 273
BCCE-VSS-200 200 304
BCCE-VSS-250 250 380
BCCE-VSS-300 300 456
BCCE-VSS-400 400 608
BCCE-VSS-500 500 760
BCCE-VSS-600 600 912
BCCE-VSS-800 800 1216
BCCE-VSS-1000 1000 1519
BCCE-VSS-1200 1200 1823
BCCE-VSS-1600 1600 2431
BCCE-VSS-2000 2000 3039
BCCE-VSD-3 3 14   220±5%Can be set Single-phase
BCCE-VSD-5 5 23
BCCE-VSD-10 10 45
BCCE-VSD-20 20 91  
BCCE-VSD-30 30 136  
BCCE-VSD-50 50 227  
BCCE-VSD-100 100 455
 

Major Function:

 

Transport

enter

Stabilizer Range

Three phase 380V + 15% to + 40%, single phase 220V + 15% to + 40% can be selected.

Frequency

47Hz-63Hz

Transport

Out of

Rated Voltage

Phase voltage 220V, line voltage 380V (other voltage can be set.

For example, 400V and so on.

Stabilized Voltage Precision

±1%

Response Time

Fast (20ms)

Waveform Distortion

No additional waveform distortion (static)

Efficiency

≥98%

Three Phase Imbalances

Automatic balance of three-phase voltage

Delay Output

First stabilizer and re output (protection equipment is not impacted)

Overvoltage

Output phase voltage exceeds 10%, cut off output or uninterrupted bypass.

Protect

 

Undervoltage

Output phase voltage below 10%, cut off output or continuous bypass bypass.

Phase Deficiency

Have (automatically cut off)

Overload

Electronic detection, overloading in 3 minutes to cut off the output

Overflow

Double protection of electronic detection and circuit breaker

Short Circuit

Double protection of electronic detection and circuit breaker

Bypass

Uninterrupted automatic bypass

Voltage

A, B, C, and sigma ABC have three RMS LCD liquid crystal display respectively.

Finger

show

Electric current

A, B, C, and sigma ABC have three RMS LCD liquid crystal display respectively.

Working Condition

Steady state / direct state

Abnormal

Overvoltage, undervoltage, overload, fuse break

Color touch screen man-machine interface

Intelligent man-machine interface operation panel, easy to set up inquiries of various parameters, and can lock the machine within the specified time.

Operation mode

Two modes of work with steady pressure and straight through

Overload capacity

5 times the rated current for 1 seconds

Interface:

BCCE-VS series intelligent contactless compensation AC voltage regulator industry first uses seven inch touch screen LCD LCD display, and can display voltage, current, fault state and working mode intuitively through LCD LCD screen. Its voltage regulation precision, output voltage, working mode, locking machine can be set by the panel, and the operation is simple, easy to understand and realize one key operation.

 

 

1.1 click 1 to enter the figure 3 parameter view interface

1.2 click 2 to enter the detailed display interface of Figure 2

1.3 click 3 to enter version information

1.4 display A phase output voltage

1.5 display B phase output voltage

1.6 display C phase output voltage

1.7 display A phase current

1.8 display B phase current

1.9 display C phase current

1.10 shows the regulator value, you can click the enter dialog box to set the required stable voltage value.

1.11 shows the accuracy of voltage regulation tolerance, you can click the enter dialog box to set the required voltage regulation accuracy.

1.12 display the change of the output voltage waveform

1.13 shows whether it is straight through, red is straight, and green is normal.

 

2.1 display A phase input voltage

2.2 display B phase input voltage

2.3 display C phase input voltage

2.4 display A phase output voltage

2.5 display B phase output voltage

2.6 display C phase output voltage

2.7 display AB phase output voltage

2.8 display BC phase output voltage

2.9 display CA phase output voltage

2.10 display A phase current

2.11 display B phase current

2.12 display C phase current

2.13 over voltage indication, green is normal and red is undervoltage.

2.14 overload indication, green is normal, red is overload.

2.15 over temperature indicates that green is normal and red is over temperature.

2.16 lack of phase indicates that green is normal and red is absent.

2.17 A phase insurance indicates that green is normal and red is broken.

2.18 B phase insurance indicates that green is normal and red is broken.

2.19 C phase insurance indicates that green is normal and red is broken.

 

3.1 display the overload current value of the machine

3.2 display machine undervoltage protection value

3.3 display the overvoltage protection value of the machine

3.4 display machine overload delay action time

3.5 display machine overvoltage drought action time

3.5 alarm switch that can be closed or open

Shape size and weight:

Phase number

Capacity (KVA)

Length * width * height (mm)

base

Number of cabinets

Weight (KG)

Three-phase

10

850*400*840

850*400

Single cabinet

130

20

138

30

146

50

175

60

175

80

900*500*1010

900*500

223

100

250

120

300

150

850*850*1400

850*850

400

180

450

200

550

250

1100*900*1600

1100*900

600

300

700

400

800

500

1300*1000*1800

1300*1000

900

600

1100

800

1300

1000

1500*1100*1800

1500*1100

1500

1200

1750

1600

1800*1200*2000

1800*1200

1900

2000

2200

Bcce-Vss (D) Series RegulatorBcce-Vss (D) Series RegulatorBcce-Vss (D) Series RegulatorBcce-Vss (D) Series RegulatorBcce-Vss (D) Series Regulator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now