• 500kVA 315V/400V Three Phase Isolating Transformer
  • 500kVA 315V/400V Three Phase Isolating Transformer
  • 500kVA 315V/400V Three Phase Isolating Transformer
  • 500kVA 315V/400V Three Phase Isolating Transformer
  • 500kVA 315V/400V Three Phase Isolating Transformer
  • 500kVA 315V/400V Three Phase Isolating Transformer

500kVA 315V/400V Three Phase Isolating Transformer

Application: Power, Electronic, Instrument, Lighting
Phase: Three
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001, CCC
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (17)

Basic Info.

Model NO.
BC-T00297A
Usage
Rectifier Transformer, Combined Transformer, Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Silicon Steel Sheet
Brand
Bc Power
No Load Output Voltage
400V +/-3%
Load Output Voltage
400V +/-3%
Isolation Grade
Class H (180 C)
Working Frequency
50Hz
Rated Power
500kVA
Noise
<70dB
Temperature Rise
<115K
Transport Package
Wooden Case
Specification
500KVA, 315V/400V
Trademark
BC POWER or Customized
Origin
Dongguan City, Guangdong Province, China
Production Capacity
3000-5000 PCS/Year

Product Description


Electric Characteristics
 
Dongguan Baocheng Power Technology Co., Ltd. is a full program of R & D, manufacturing and sales as one of the magnetic devices. It specializes in designing and customizing the "magnetic devices" of modern power electronic systems for customers, including applications from power frequency to high frequency, from low voltage to high voltage, and high frequency and high voltage. The system covers all kinds of dry / water-cooled inductors, reactors, transformers and transformer cabinets. The power range of the product covers 50VA-5000KVA, the frequency range covers 50Hz-50 KHz, the voltage level covers all kinds of high / low voltage, high / frequency products, and the K- coefficient of application in the non linear load environment. Press (patent product) etc.

Company founded in 2010. The company's headquarters is located in Jinhe community of Zhangmutou town in Dongguan. The practical area of the factory is about 10 thousand square meters. It sets up distribution outlets in East China, North China, northwest and other places. It is a high-tech enterprise in Dongguan. The company has more than 20 patents.

No. Parameter Test Terminal Test Value Test Condition Standard Test Instrument
1 No Load Output Voltage a-b, b-c, c-a 400V(+/-3%) Input: A-B, B-C, C-A 315V Transformer Comprehensive Tester
2 Rated Load Voltage a-b, b-c, c-a 400V(+/-3%) Input: A-B, B-C, C-A 315V
3 Rated Load Power   500KVA  
4 Rated Load Current a-b, b-c, c-a 721.7A Input: A-B, B-C, C-A 315V
5 Overload Operation Not overtemperature with 110% load at 45 degree C ambient temperature  for 1.5 hours
6 Coil vector connection   Dyn 11  
7 Efficiency   >97.85%
>98%
With 500kW resistive load
With 400kW resistive load
8 Short circuit impedance   <8.5%  
9 Insulation resistance Parallel rod to iron core >100MΩ 500V DC 500V DC tramegger
10 Dielectric strength Primary/Secondary to GND; Secondary-Primary-Temperature relay, temperature relay-Iron core leak current<35mA/no arcing breakdown 3000VAC/60S

3000VAC/60S
Power frequency tester
11 Temperature rise Hottest spot in coil <115K Rated full load, air forced cooling K-type thermocouple
12 Noise   <70dB At one meter distance Noise meter
13 Insulation grade   H    
14 Surge current a-b, b-c, c-a <5 In Output: a-b, b-c, c-a 400V Transformer Comprehensive Tester
15 No load current A B C <3% Input: A-B, B-C, C-A 315V
16 DC bias A B C 50A Input: A-B, B-C, C-A 315V
17 Withstand ripple current  Estimate according to the rated current of 315V side 5% rated current Input: A-B, B-C, C-A 315V
18 Voltage Range Long term operating voltage range -85%~+125% 400V side
19 Heat dissipating method Forced cooling     No built-in fan
20 Storage temperature -40ºC~70ºC
21 Full load operating temperature -40ºC~55ºC,derating use above 55ºC
22 Operating humidity Relative 0%~95%; abosolute: < 29g /m3, no condensation
23 Application of altitude 0~4000m, rated current under 2000m, derating 1% for every 100m rise above 2000m
24 Polution prevention Level 2
25 Salt spray resistance rating Salt content 0.1mg/m3
500kVA 315V/400V Three Phase Isolating Transformer500kVA 315V/400V Three Phase Isolating Transformer500kVA 315V/400V Three Phase Isolating Transformer500kVA 315V/400V Three Phase Isolating Transformer500kVA 315V/400V Three Phase Isolating Transformer