• Bc-AC380-21kw-R Load Cabinet
  • Bc-AC380-21kw-R Load Cabinet
  • Bc-AC380-21kw-R Load Cabinet
  • Bc-AC380-21kw-R Load Cabinet
  • Bc-AC380-21kw-R Load Cabinet
  • Bc-AC380-21kw-R Load Cabinet

Bc-AC380-21kw-R Load Cabinet

Power Factor: 1
Protection: Emergency Stop Protection/Short Circuit Protection
Display: Voltage, Current, Power, Frequency etc
Rated Voltage: Three-Phase AC380V
Rated Power: 21kw
Frequency: 50Hz
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (17)

Basic Info.

Model NO.
BC-E00044A
Accuracy of Load
<+/-5%
Fan Noise
75dB
Cooling Mode
Forced Air Cooling
Moving Method
It Is Equipped with 4 Wheels of Mobile Feet, 2 in
Applicable Ambient Temperature
-10~+55 Degree C
Applicable Relative Humidity
<90%
Height Above Sea Level
<2000 M
Transport Package
Shipping with Wooden Box
Specification
600mm*750mm*1120mm as per Customer′s requirement
Trademark
BC POWER or as per Customized
Origin
Dongguan City, Guangdong Province, China
Production Capacity
300~500PCS/Year

Product Description

Product Description

RCD load is a kind of nonlinear analog load, which can be used to test the power generation unit of data center, UPS and other power supply equipment, to understand the real working ability of the nonlinear load such as computer and network equipment. Through accurate detection of power output and quality of power supply, it can avoid driving load or pollution to power grid in actual use, so as to ensure the safety of power supply.

With the development of digitalization and networking in modern society, rectifying loads such as computers and network devices are widely used. The load composed of rectifier and filter circuit has nonlinear characteristics, and its resistance is not constant. It has higher requirements for the output range and stability of the power supply equipment. Therefore, for the data center backup generator, network power supply UPS and other power supply equipment, the analog load with nonlinear characteristics must be used to test the peak factor and other parameters.
However, the traditional RLC analog load is based on the linear load, which can not simulate the change characteristics of the nonlinear load, and it is difficult to test the actual performance of the starting power unit, the UPS in the data center and the network power environment. Only by using RCD nonlinear load can we make the most accurate judgement of the output power and power quality of the power supply equipment. At present, there are still no mature technical specifications and application cases in this field.

This product can be widely used in data center, network communication, finance, insurance, school and other fields such as backup generator, UPS power supply detection and maintenance, fill the market gap.
 

Main functions and parameters:

  1. The nonlinear load of RCD is composed of resistive load, capacitive load and analog impedance resistor. The impedance of the load can be adjusted by the input analog impedance of an independent circuit. The load power can be nonlinear loaded.
  2. The power factor of the load reference is 0.7, and the power factor can be adjusted in the range of 0.2-1 through the free combination of active power and reactive power.
  3. The rated voltage and rated power of the load can be customized according to the needs of users.
  4. After loading, the voltage, current, active power, reactive power, power, power factor, frequency and other parameters can be measured, and the user can be used to test the peak factor.
  5. Through harmonic analysis, the 2~50 harmonic content and total harmonic content of voltage and current can be detected, and the quality of power supply under the condition of nonlinear load can be detected.
  6. Load with multi-function measuring instrument, can display voltage, current, power, power factor, frequency and other parameters.
  7. Through computer software control load, automatic test can be realized, and test data can be displayed, recorded and managed.
  8. All test data can be stored in the software database, and can be Querying Historical test data at any time, exported to Excel and other general format files, and support printing.
  9. The load has multiple protection functions, such as overvoltage, overcurrent, overheating, fan abnormal and so on. The load can be automatically unloaded when the load is dangerous. It can also be forced to unload by manual stop switch.
Equipment Technical Parameters
Item Parameters Value or Description
1 Rated Voltage Three-phase AC380V
2 Rated Power 21KW
3 Frequency  50Hz
4 Power Factor 1
5 Power Step A/B/C:100W,200W,200W,500W,1KW,2KW,3KW, total 7 gears, 7KW each phase, 21KW in total three-phase(100W-21KW, can be used for any combination)
6 Display Mode Voltage, Current, Power Factor, Frequency, Active Power, Reactive Power, etc
7 Overload Capacity(Current Loop) 1.2 times rated current
8 Rated Current 32A
9 Accuracy of Load Resistive load +/-5%, Capacitive load +/-5%
10 Working Power AC220V+/-10%
11 Control Mode(2 modes can be switched to use) Local buttons control loading/unloading
Remote upper computer: 485 serial port communication, tap point moving, program controlled emergency stop, real-time display of data acquisiton, data saving and support printing
12 Protection Grade  IP20(Suitable for indoor use)
13 Fan noise 75dB
14 Cooling Mode Forced air cooling
15 Protective Function Emergency stop protection/short circuit protection/over temperature protection/over temperature alarm/buzzing prompt
16 External Dimension Approximate width 600mm depth 750mm height 1120mm(subject to the actual design size)
17 Moving method It is equipped with 4 wheels of mobile feet, 2 in front and 2 in back for convenient movement
18 Applicable Ambient Temperature  -10ºC-+55ºC
19 Applicable Relative Humidity <90%
20 Height above sea level <2000 M

The product is customized according to the customer's request.

 

Detailed Photos

Bc-AC380-21kw-R Load CabinetBc-AC380-21kw-R Load CabinetBc-AC380-21kw-R Load CabinetBc-AC380-21kw-R Load CabinetBc-AC380-21kw-R Load Cabinet

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
27
Year of Establishment
2011-03-25